Skip to content
  1. Home

Frequently asked questions

Answers to the questions customers ask us most, from choosing and fitting a dimmer to curing flicker. Search, or browse by product or topic.

Showing 23 questions about V-Pro Multiway Show all questions

Choosing a dimmer

Which dimmer suits your lights, how much lighting it can take, and dimming from more than one switch.

Which dimmer do I need for my LED bulbs?

For dimmable LED lighting choose a V-Pro dimmer: our flagship range, designed for modern LED lighting, with push on/off switching and rotary dimming. In the European ranges the V-Pro family also includes:

  • V-Pro Multiway: a dimming knob at 2 or 3 switch positions;
  • V-Pro Micro: hidden behind retractive (push) switches.

If your LED lights or driver need leading-edge (triac) control, choose V-Com. Always choose lamps that are described as dimmable.

Copy link and share

How many lamps can my dimmer control?

Add up the wattage of all the lamps the dimmer controls: the number of lamps times the watts printed on each. The total must not be more than the maximum load per gang on the dimmer's label and data sheet. For example, 8 LED downlights of 5W each add up to 40W.

DimmerLoad per dimmer (gang)
V-Pro0-120W or 0-300W, no minimum load
V-Pro Multiway120W (master dimmers 100W), no minimum load
V-Pro Micro160W of dimmable LED
V-Com0-100W, 0-180W or 15-180W (the first figure is the minimum)
V-Dim (halogen)60-400W, or 40-250W on 2-gang dimmers

With low voltage lighting, add up the VA ratings of the transformers, not the wattage of the bulbs.

Copy link and share

Is there a minimum load? Can I dim just one LED lamp?

V-Pro, V-Pro Multiway and V-Pro Micro dimmers have no minimum load, so they can dim a single LED lamp.

Some V-Com dimmers and every V-Dim dimmer have a minimum: it is the first figure of the rating on the label, for example 15-180W. The 0-100W and 0-180W V-Com dimmers have none. Below the minimum the lights may flicker: see flicker caused by too little load.

Copy link and share

Can I dim the same lights from more than one switch?

Yes. Choose by how you want to dim:

  • A dimming knob at every switch (2 or 3 positions): one V-Pro Multiway dimmer with one or two companion controllers.
  • Push (retractive) switches at any number of positions: a V-Pro Micro in-line dimmer pack.

Ordinary switches can't be used as the other positions with V-Pro Multiway: it needs companion controllers. If dimming from one switch is enough, a V-Pro dimmer works with an ordinary 2-way switch.

Copy link and share

Will my LED lamps work with your dimmers?

Our dimmers are designed for wide compatibility and are tested with many lamp types, including Megaman and Philips, which have performed well in testing. However, due to constant changes in LED technology and driver designs, we cannot guarantee compatibility with all lamps.

Before purchasing, please check our compatibility guide and the dimmer selection guide to make sure the lighting load you have is compatible with the dimmer you have chosen.

Copy link and share

Can I replace just the dimmer module in my existing plate?

Yes. Our European replacement dimmer modules fit our European dimmer plates. Remove the knob and the front plate, unscrew the nut, take the old module out from the back and fit the new one.

Each module is 64 x 58 x 46mm. Its data sheet shows the instructions and where to buy it.

Copy link and share

Setting up and programming

Dimming modes, minimum and maximum brightness, resets, and pairing supplementary controllers, remotes and the app.

V-Pro and V-Com rotary dimmers

What is child lock, and how do I turn it on or off?

Child lock stops the dimmer going into programming mode by accident. If you can't get the dimmer to program, turn child lock off first. On V-Pro and V-Com dimmers:

  1. Set the knob to maximum and switch on and off twice.
  2. Set the knob to minimum and switch on and off twice.
  3. Set the knob to maximum and switch on, off, on.
  4. The lights step to confirm the lock is on.

Repeat the same steps to turn it off. V-Pro Multiway: see Multiway programming. Watch the child lock video on VARILIGHT TV.

Copy link and share

I've changed the bulbs on my dimmer: do I need to do anything?

Yes. Always turn off the mains power before replacing bulbs controlled by a dimmer. If you have changed the type of bulb, reset the dimmer to its factory settings: see V-Pro and V-Com, V-Pro Multiway or V-Pro Micro in set up your dimmer.

Copy link and share

Some LEDs won't come on at low brightness: what is Drive (Boost)?

Drive gives LEDs that won't switch on at low brightness a short boost at start-up. On V-Pro and V-Com dimmers:

  1. Set the knob to minimum.
  2. Switch the lights on and off once per second.
  3. Set the knob to maximum, and switch on and off again.
  4. Set the knob to minimum and switch the lights on.
  5. In configuration mode, turn the knob up until the lamps switch on.
  6. Leave it for 5 seconds to save.

To turn Drive off, repeat the steps but skip step 5. The same feature is called Boost on V-Pro Multiway and on the V-Pro Micro, where it is set from the switch: see set up your dimmer.

Copy link and share

V-Pro Multiway

How do I program a V-Pro Multiway dimmer?

Settings are changed with the knob on the dimmer (not a companion controller). "Hold" means press and hold the knob.

  • Minimum brightness: set to minimum and hold for 6 seconds. The lights come on so you can adjust the minimum. Leave the dimmer for 3 seconds; the lights flash to show the new level is set.
  • Maximum brightness: set to maximum and hold for 6 seconds. When the lights blink, turn the knob to adjust. Leave it for 3 seconds; the lights flash to confirm.
  • Dimming mode: turn the dimmer off, then hold for 6 seconds. The lights pulse and go off. Press once for mode 1, twice for mode 2 or three times for mode 3 (mode 1 is the default).
  • Boost (for LEDs that don't light at low brightness): turn the dimmer off, then hold for 12 seconds, ignoring the blink at 6 seconds. The lights come on so you can set the boost level.
  • Child lock: set to minimum and hold for 12 seconds, ignoring the blink at 6 seconds. On: the lights come on for 2 seconds and go off. Off: the lights flash twice and go off.
  • Factory reset: set to maximum and hold for 12 seconds, ignoring the blink at 6 seconds. The lights come on and fade to off.

If the dimmer won't program, turn child lock off first. Full instructions: V-Pro Multiway leaflet (PDF), or pick the setting in set up your dimmer.

Copy link and share

Fitting and wiring

Wiring 2-way and multi-way circuits, wall box depths and where to find the instructions. If in doubt, consult a qualified electrician.

Dimmers

I have three or more switches (intermediate): can I fit a dimmer?
  • Dim from one switch: a push on/off V-Pro or V-Com dimmer replaces one of the switches and the others stay as they are: see the 3-way (intermediate) switch and dimmer diagram on our wiring diagrams page.
  • Dim from all three: V-Pro Multiway with two companion controllers.
  • Dim from more than three: V-Pro Micro (any number of retractive switches).

Copy link and share

How do I wire V-Pro Multiway companion controllers?

Use one V-Pro Multiway dimmer with up to two V-Pro Multiway companion controllers, for rotary dimming at each position. The companion controllers replace the other switches. Link them to the dimmer at the S and Live terminals; their third terminal takes the neutral or, where there is no neutral, a link to the dimmer's load terminal. Never connect neutral to the main dimmer.

Standard or retractive switches are not compatible: only use V-Pro Multiway companion controllers. The total cable length from the dimmer to the furthest companion controller must not exceed 50m. The V-Pro Multiway and companion controller instructions are on the instruction leaflets page.

Copy link and share

Do I need a neutral wire?
  • V-Pro Multiway dimmers: no. They install in place of a standard switch, and neutral must never be connected to the dimmer itself.
  • V-Pro and V-Com rotary dimmers: no. They connect to the switch wires only (terminals C, L1 and L2).
  • V-Pro Multiway companion controllers: they can be wired with or without a neutral (see the companion controller instructions on the instruction leaflets page).
  • V-Pro Micro: no neutral is needed at the switch. Follow the leaflet: it warns not to connect the neutral to the main dimmer unit.

Copy link and share

What wall box do the European ranges need?

The European fixed range and the European VariGrid range fit a standard European 40mm round or square wall box. Fix them with the screws or the claws supplied: see fitting a European fixed range product, fitting a VariGrid plate and the European fitting instructions (VEU001) on the instruction leaflets page.

The wall box for a particular product is also on its data sheet: type the product code into the search box. See also wall box depths.

Copy link and share

Where can I find the instructions or a wiring diagram for my product?

The instruction leaflet, with its wiring diagrams, comes with your product. You can also find every current leaflet on the instruction leaflets page, and leaflets for older and discontinued products on the earlier leaflets page. Where relevant, check the software version and choose the correct leaflet: the software version is on the side of the dimmer module.

We also have a page of wiring diagrams and how-to videos. Every data sheet links to the product's leaflet: type the product code into the search box. If the wiring diagram is not enough, please contact a qualified electrician.

Copy link and share

What do I need to remove before an insulation test?

Dimmers from all of our ranges should be disconnected for the duration of the insulation resistance test. Failing to do so could damage the dimmer and make the product guarantee invalid.

Copy link and share

Parts, finishes and care

Knobs and spare parts, product codes and data sheets, finishes, cleaning and decorating.

Where can I get a replacement dimmer knob?

All our knobs have the same fixing, so they fit every VARILIGHT dimmer. Screwless products need a "pipped" knob, which is slightly raised for spacing. Pipped knobs aren't sold separately: for a replacement, please send us a message or email help@varilight.co.uk and our customer services team will help.

Spare knobs are sold singly or in packs of 10 (the same code with 10 on the end). Click a code for its data sheet, which shows where to buy it:

Copy link and share

Guarantee and older products

The lifetime guarantee, how to claim, and help for products we no longer make.

How do I make a guarantee claim or return a faulty product?

Many problems can be solved without a replacement, so please check the troubleshooting answers first. Then:

  1. Send us a message, or email help@varilight.co.uk, with your purchase details and a description of the problem. Tell us the product code, the batch number (on the plastic moulding at the back of a dimmer), the type and wattage of the lamps it controls, and the fault. Keep your proof of purchase.
  2. The faulty product must be returned: we'll tell you where to send it, to VARILIGHT in the UK or to Varilight Europe Kft in Hungary (both addresses are in the instruction leaflet). Pack it securely with your proof of purchase, your contact details and return address, the type and wattage of the lighting or other load, and the details of the fault.
  3. If the claim is approved, we'll repair or replace the product.

See our lifetime guarantee.

Copy link and share

Where do I find the batch number or software version?

The batch number is printed on the plastic moulding at the back of the dimmer module: on the side or the bottom, depending on the model. The leaflet has a space to record it, and it helps us give you the right technical support. Where it applies, the software version is on the side of the dimmer module: use it to choose the right instruction leaflet.

Copy link and share

Troubleshooting

Dimmers that have stopped working, flicker, buzz or glow, and other problems with installed products.

Not working, or switching off

My dimmer has stopped working: what should I do?

Many faults can be cleared without replacing anything. Switch off at the mains before touching any wiring and, if in doubt, consult a qualified electrician.

  1. Reset the power. Switch the lighting circuit off at the circuit breaker, then back on after a few seconds. An overloaded dimmer switches itself off to protect itself.
  2. Check the load. Add up the wattage of all the lamps on the dimmer (for low voltage lighting, the VA ratings of the transformers). It must not be more than the maximum per gang on the dimmer's label. See how many lamps a dimmer can control.
  3. Changed the bulbs? If you have changed the type of lamp, reset the dimmer to its factory settings: see set up your dimmer.
  4. New installation? Check the wiring against the diagram in the instruction leaflet.
  5. Lights come on but won't dim? See my dimmer won't dim the lights.

If it still doesn't work, the dimmer may be faulty. It is covered by our lifetime guarantee: see how to make a claim. It helps to have the product code, the batch number (printed on the plastic moulding at the back of the dimmer) and the type and wattage of your lamps to hand.

Copy link and share

Flickering, buzzing and glowing

My LED lights flicker: how do I stop it?

Most flicker can be cured with the dimmer's own settings. On V-Pro and V-Com dimmers:

  • Flicker at low brightness: raise the minimum brightness.
  • Flicker at high brightness: lower the maximum brightness.
  • Flashing at any level: change the dimming mode. Mode 1 suits most LEDs; some perform better in Mode 2 or, in some cases, Mode 3.

Also check that the lamps are described as dimmable, and are all of the same type: our dimmers are not designed for mixed lighting types on one circuit; that on a 2-way circuit only one of the switches has been replaced with a dimmer; and, if your dimmer has a minimum load (the first figure of the rating on some V-Com and every V-Dim dimmer), that the lamps add up to more than it: see flicker caused by too little load.

V-Pro Multiway and V-Pro Micro dimmers have the same kind of settings: see set up your dimmer.

Copy link and share

My lights won't dim low enough, or go off at the lowest setting
  • Too bright at the lowest setting: reduce the dimmer's minimum brightness.
  • Off or flickering at the lowest setting: raise the minimum brightness.
  • If some LEDs won't switch on at low brightness, turn on Drive (Boost), which gives them a short boost at start-up.

When the dimmer is installed, all the lamps must stay visibly on at the lowest brightness setting (EU Ecodesign Regulation 1194/2012). How low a lamp will dim varies according to the brand and type of LED. The same settings on V-Pro Multiway and V-Pro Micro (set from the switch): see set up your dimmer.

Copy link and share

My LED lamps start slowly or take time to reach full brightness

The V-Pro soft-start function gradually increases power over approximately 1 second to protect against inrush current and improve lamp life. LED drivers vary widely in design, so some may start differently or take longer to reach full brightness.

Changing the driving mode on the dimmer may improve this behaviour, although results cannot be guaranteed due to lamp variability.

Copy link and share

Still stuck?

Our customer services team will help. To get the quickest answer, tell us the product code, the batch number from the back of the dimmer, and the make, wattage and number of lamps.